Greenheck out of wall fire smoke damper
WebRound Fire and Combination Fire Smoke Dampers' (Part #481319) or "GFSD-xxx series Grille Access Out of Wall/Floor Combination Fire Smoke Dampers' (Part #472477) or 'OFSD-xxx, ODFD-xxx, and OFD-xxx Out of Wall/Floor Combination Fire Smoke and Fire Dampers' (Part #461337) for additional details. 1½ in. x 1½ in. x 2 in. minimum angle … WebDamper/sleeve assemblies must be installed in wall openings using flanges and sheet metal screws as illustrated and describe below. This method is only applicable to 11/2 hour rated damper; the 3 hour damper and dampers larger than 36 in. x 36 in. (914 mm x 914 mm) will require a minimum of 11/2 in. x 11/2 in. (38 mm x 38 mm) legs.
Greenheck out of wall fire smoke damper
Did you know?
WebThe FSD-211 is a combination fire smoke damper with 3V-style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg. Velocity: Up to 2,000 fpm. Temperature: Up to 350°F. 10-Day Fixed Lead Times on Select Configurations. Watch Now to Learn More! Certifications: WebModel OFD-150 is a static rated out of wall fire damper for use in HVAC systems that are automatically shut down in the event of a fire. This fire damper is rated for use in walls or partitions with less than 3 hour fire resistance rating and can be mounted vertically or horizontally. Removal of grille allows access to the damper and fusible ...
WebOut of Wall Fire Smoke Dampers Combination Fire Smoke Dampers with a 1½ hour fire rating – UL 555 and UL 555S Classified Combination fire and smoke dampers are used … WebFire Dampers Fire dampers are required by all building codes to maintain the required fire resistance ratings of walls, partitions and floors when they are penetrated by air ducts and transfer openings. These products are tested and classified in accordance with UL Standard 555. Fire dampers
WebModel OFD-150 is a static rated out of wall fire damper for use in HVAC systems that are automatically shut down in the event of a fire. This fire damper is rated for use in walls … WebThe SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg. Velocity: Up to 2000 fpm. Temperature: Up to 350°F.
WebA: The damper location for all multi-blade models (FSD, SMD, VCD and DFD-210 series) is referred to as the A dimension (distance from end of sleeve to face of damper). The minimum space allowed is 182.575 millimeters (7.188 inches) and is the default in CAPS. The damper location for curtain style fire dampers (FD and DFD) is referred to as the K …
WebSep 8, 2024 · Fire dampers carry a fire-resistance rating of 1 ½ or 3 hours, equating to the length of time exposed to the fire test. A 1 ½ hour rated fire damper may be installed into walls, floors, or partitions having a fire-resistance rating of less than 3 hours, while any assembly with a rating of 3 hours or more requires a 3 hour rated fire damper ... how to say athletic in spanishWebRound combination fire smoke dampers function as both a fire damper (1 ½ hour rating) and a smoke damper (UL leakage class of I or II). ... Greenheck’s damper interactive selection guide removes the guesswork. Find blade type, velocity, pressure, AMCA listings, submittals, drawings and more, all in one easy-to-use format. how to say athlete in spanishWebModel OFSD-311 is an ‘out of wall’ high performance combination fire smoke damper with Class I leakage. The OFSD-311 is approved for use in walls, partitions, and floors with fire resistance ratings less than 3 hours. Removal of wall grille allows access to the actuator and other components. High strength how to say at home in frenchWebGreenheck-USA how to say atlas in spanishWebLeakage (Smoke) Damper Listing (#3230-0981:0104) *Width and Height dimensions furnished approximately 1⁄ 4 in. (6mm) undersize. Add blanket thickness (1⁄ 8 in. [3mm]) and sleeve thickness for overall sleeved damper dimension. Oversize wall opening as follows: Nominal damper size plus 3⁄ 8 in. (9.5mm). GFSD-211 Out of Wall Combination Fire ... how to say athletesWebCSFM California State Fire Marshal Fire Damper Listing (#3225-0981:0103) Leakage (Smoke) Damper Listing (#3230-0981:0104) *only availabe with fusible link Note: The frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high for lower pressure drop and improved damper … how to say at home in spanishWebSee notes 4,5, and 7 Fire or Combination Fire Smoke Damper Figure 2: Factory sleeve ends in the plane of the rated barrier. ® Sleeve Extensions 1 ® Document 462103 Sleeve Extensions nstallation nstruction Supplement FD DFD Series Fire Dampers and FSD Series Combination Fire Smoke Dampers north fifth brewing